<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE root>
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:ali="http://www.niso.org/schemas/ali/1.0/" article-type="other" dtd-version="1.2" xml:lang="en"><front><journal-meta><journal-id journal-id-type="publisher-id">Digital Diagnostics</journal-id><journal-title-group><journal-title xml:lang="en">Digital Diagnostics</journal-title><trans-title-group xml:lang="ru"><trans-title>Digital Diagnostics</trans-title></trans-title-group><trans-title-group xml:lang="zh"><trans-title>Digital Diagnostics</trans-title></trans-title-group></journal-title-group><issn publication-format="print">2712-8490</issn><issn publication-format="electronic">2712-8962</issn><publisher><publisher-name xml:lang="en">Eco-Vector</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="publisher-id">697275</article-id><article-id pub-id-type="doi">10.17816/DD697275</article-id><article-categories><subj-group subj-group-type="toc-heading" xml:lang="en"><subject>Original Study Articles</subject></subj-group><subj-group subj-group-type="toc-heading" xml:lang="ru"><subject>Оригинальные исследования</subject></subj-group><subj-group subj-group-type="toc-heading" xml:lang="zh"><subject>原创性科研成果</subject></subj-group><subj-group subj-group-type="article-type"><subject></subject></subj-group></article-categories><title-group><article-title xml:lang="en">Practical application of a quality control tool for chest X-ray images. The results of the pilot experiment.</article-title><trans-title-group xml:lang="ru"><trans-title>Практическое применение инструмента контроля качества рентгенографических исследований органов грудной клетки. Результаты пилотного эксперимента</trans-title></trans-title-group><trans-title-group xml:lang="zh"><trans-title/></trans-title-group></title-group><contrib-group><contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0003-4036-5883</contrib-id><contrib-id contrib-id-type="scopus">58236812800</contrib-id><contrib-id contrib-id-type="researcherid">HCI-7802-2022</contrib-id><contrib-id contrib-id-type="spin">4294-4736</contrib-id><name-alternatives><name xml:lang="en"><surname>Borisov</surname><given-names>Aleksandr</given-names></name><name xml:lang="ru"><surname>Борисов</surname><given-names>Александр Александрович</given-names></name><name xml:lang="zh"><surname></surname><given-names></given-names></name></name-alternatives><address><country country="RU">Russian Federation</country></address><email>aleksandrborisov10650@gmail.com</email><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-7786-0349</contrib-id><contrib-id contrib-id-type="spin">3160-8062</contrib-id><name-alternatives><name xml:lang="en"><surname>Arzamasov</surname><given-names>Москва, Россия.</given-names></name><name xml:lang="ru"><surname>Арзамасов</surname><given-names>Кирилл Михайлович</given-names></name><name xml:lang="zh"><surname></surname><given-names></given-names></name></name-alternatives><address><country country="RU">Russian Federation</country></address><bio xml:lang="en"><p>PhD</p></bio><bio xml:lang="ru"><p>Доктор медицинских наук</p></bio><email>ArzamasovKM@zdrav.mos.ru</email></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-0245-4431</contrib-id><contrib-id contrib-id-type="spin">8948-6152</contrib-id><name-alternatives><name xml:lang="en"><surname>Omelyanskaya</surname><given-names>Olga</given-names></name><name xml:lang="ru"><surname>Омелянская</surname><given-names>Ольга Васильевна</given-names></name><name xml:lang="zh"><surname></surname><given-names></given-names></name></name-alternatives><address><country country="RU">Russian Federation</country></address><email>OmelyanskayaOV@zdrav.mos.ru</email><xref ref-type="aff" rid="aff6"/></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-2990-7736</contrib-id><contrib-id contrib-id-type="spin">3602-7120</contrib-id><name-alternatives><name xml:lang="en"><surname>Vladzymyrskyy</surname><given-names>Anton</given-names></name><name xml:lang="ru"><surname>Владзимирский</surname><given-names>Антон Вячеславович</given-names></name><name xml:lang="zh"><surname></surname><given-names></given-names></name></name-alternatives><bio xml:lang="en"><p>PhD</p></bio><bio xml:lang="ru"><p>Доктор медицинских наук</p></bio><email>VladzimirskijAV@zdrav.mos.ru</email><xref ref-type="aff" rid="aff8"/></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-5283-5961</contrib-id><contrib-id contrib-id-type="spin">4458-5608</contrib-id><name-alternatives><name xml:lang="en"><surname>Vasilev</surname><given-names>Yuriy</given-names></name><name xml:lang="ru"><surname>Васильев</surname><given-names>Юрий Александрович</given-names></name><name xml:lang="zh"><surname></surname><given-names></given-names></name></name-alternatives><bio xml:lang="en"><p>PhD</p></bio><bio xml:lang="ru"><p>Доктор медицинских наук</p></bio><email>VasilevYA1@zdrav.mos.ru</email><xref ref-type="aff" rid="aff10"/></contrib></contrib-group><aff-alternatives id="aff1"><aff><institution xml:lang="en">Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Health Care Department</institution></aff><aff><institution xml:lang="ru">Государственное бюджетное учреждение здравоохранения города Москвы «Научно-практический клинический центр диагностики и телемедицинских технологий Департамента здравоохранения города Москвы», Москва, Россия.</institution></aff><aff><institution xml:lang="zh"></institution></aff></aff-alternatives><aff-alternatives id="aff2"><aff><institution xml:lang="ru">ФГАОУ ВО Российский Национальный Исследовательский Медицинский Университет им. Н.И. Пирогова МЗ РФ, Москва, Россия</institution></aff><aff><institution xml:lang="en">State Budget-Funded Health Care Institution of the City of Moscow "Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Health Care Department", Moscow, Russia</institution></aff><aff><institution xml:lang="zh"></institution></aff></aff-alternatives><aff-alternatives id="aff3"><aff><institution xml:lang="en">Samara State Medical University, Samara, Russia</institution></aff><aff><institution xml:lang="ru">Государственное бюджетное учреждение здравоохранения города Москвы «Научно-практический клинический центр диагностики и телемедицинских технологий Департамента здравоохранения города Москвы», Москва, Россия</institution></aff><aff><institution xml:lang="zh"></institution></aff></aff-alternatives><aff-alternatives id="aff4"><aff><institution xml:lang="en">MIREA – Russian Technological University, Moscow, Russia.</institution></aff><aff><institution xml:lang="ru">ФГБОУ ВО Самарский Государственный Медицинский Университет МЗ РФ, Самара, Россия</institution></aff><aff><institution xml:lang="zh"></institution></aff></aff-alternatives><aff-alternatives id="aff5"><aff><institution xml:lang="ru">ФГБОУ ВО «МИРЭА — Российский технологический университет», Москва, Россия.</institution></aff><aff><institution xml:lang="en">State Budget-Funded Health Care Institution of the City of Moscow "Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Health Care Department", Moscow, Russia</institution></aff><aff><institution xml:lang="zh"></institution></aff></aff-alternatives><aff-alternatives id="aff6"><aff><institution xml:lang="en">MIREA – Russian Technological University, Moscow, Russia.</institution></aff><aff><institution xml:lang="ru">Государственное бюджетное учреждение здравоохранения города Москвы «Научно-практический клинический центр диагностики и телемедицинских технологий Департамента здравоохранения города Москвы», Москва, Россия</institution></aff></aff-alternatives><aff-alternatives id="aff7"><aff><institution xml:lang="ru">ФГБОУ ВО «МИРЭА — Российский технологический университет», Москва, Россия.</institution></aff><aff><institution xml:lang="en">State Budget-Funded Health Care Institution of the City of Moscow "Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Health Care Department", Moscow, Russia</institution></aff></aff-alternatives><aff-alternatives id="aff8"><aff><institution xml:lang="en">Federal State I.M. Sechenov First Moscow State Medical University of the Ministry of Health of the Russian Federation (Sechenov University), Moscow, Russia.</institution></aff><aff><institution xml:lang="ru">Государственное бюджетное учреждение здравоохранения города Москвы «Научно-практический клинический центр диагностики и телемедицинских технологий Департамента здравоохранения города Москвы», Москва, Россия</institution></aff></aff-alternatives><aff-alternatives id="aff9"><aff><institution xml:lang="ru">ФГАОУ ВО Первый Московский государственный медицинский университет имени И.М. Сеченова МЗ РФ (Сеченовский Университет), Москва, Россия.</institution></aff><aff><institution xml:lang="en">State Budget-Funded Health Care Institution of the City of Moscow "Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Health Care Department", Moscow, Russia.</institution></aff></aff-alternatives><aff id="aff10"><institution>Государственное бюджетное учреждение здравоохранения города Москвы «Научно-практический клинический центр диагностики и телемедицинских технологий Департамента здравоохранения города Москвы», Москва, Россия</institution></aff><pub-date date-type="preprint" iso-8601-date="2026-06-05" publication-format="electronic"><day>05</day><month>06</month><year>2026</year></pub-date><volume>7</volume><issue>2</issue><issue-title xml:lang="ru"/><history><date date-type="received" iso-8601-date="2025-12-02"><day>02</day><month>12</month><year>2025</year></date><date date-type="accepted" iso-8601-date="2026-05-12"><day>12</day><month>05</month><year>2026</year></date></history><permissions><copyright-statement xml:lang="en">Copyright ©; , Eco-Vector</copyright-statement><copyright-statement xml:lang="ru">Copyright ©; , Эко-вектор</copyright-statement><copyright-statement xml:lang="zh">Copyright ©; , Eco-Vector</copyright-statement><copyright-holder xml:lang="en">Eco-Vector</copyright-holder><copyright-holder xml:lang="ru">Эко-вектор</copyright-holder><copyright-holder xml:lang="zh">Eco-Vector</copyright-holder><ali:free_to_read xmlns:ali="http://www.niso.org/schemas/ali/1.0/"/><license><ali:license_ref xmlns:ali="http://www.niso.org/schemas/ali/1.0/">https://creativecommons.org/licenses/by-nc-nd/4.0</ali:license_ref></license></permissions><self-uri xlink:href="https://jdigitaldiagnostics.com/DD/article/view/697275">https://jdigitaldiagnostics.com/DD/article/view/697275</self-uri><abstract xml:lang="en"><p><bold><italic>BACKGROUND: </italic></bold>According to the literature, the proportion of studies with various quality impairments for chest X-ray is from 9 to 50%. Evaluation of the quality of radiographic diagnostic studies is an important stage of the diagnostic process, which makes it possible to identify low–quality images that negatively affect the diagnosis of various pathological conditions. At the moment, the quality assessment is carried out manually, which is complicated by the conditions of remote description of research and high workload. We have developed a quality control Tool that allows us to automatically assess the presence of impairments of the patient's positioning on the chest X-ray, as well as identify errors in filling out meta-information about the study in DICOM format.</p> <p><bold><italic>AIM:</italic></bold><italic> </italic>Evaluation of the effectiveness of a quality control Tool in real diagnostic practice.</p> <p><bold><italic>METHODS:</italic></bold><italic> </italic>The pilot experiment was conducted in 3 outpatient medical organizations in Moscow during two months. As part of the experiment, 9642 chest X-ray images were processed with the Tool. The images were then evaluated by radiologists to confirm the presence of quality impairments.</p> <p><bold><italic>RESULTS:</italic></bold><italic> </italic>The average processing time for one study was 14 seconds. During the pilot experiment, 3386 different patient positioning impairments were detected, occurring on from 14 to 45% of radiographic images. It was also revealed that the accuracy of filling in various meta-information about the study ranges from 14 to 100%. The quality control Tool coped with the detection of patient positioning violations with an AUC from 0.782 to 0.947 and with the detection of errors in filling in meta-information with an AUC from 0.985 to 1.0.</p> <p><bold><italic>CONCLUSION: </italic></bold>The automated quality control Tool has proven to be promising in identifying impairments in filling out meta-information about the study and patient positioning. The scheme of integrating the Tool into the quality control process made it possible to obtain the evaluation result 14 seconds after the research. If this scheme is optimized, this time can be shortened.</p></abstract><trans-abstract xml:lang="ru"><p><bold>Обоснование. </bold>По данным литературы, доля исследований с различными нарушениями качества для рентгенографии органов грудной клетки составляет от 9 до 50%. Оценка качества лучевых диагностических исследований – важный этап диагностического процесса, позволяющий выявлять некачественные изображения, негативно влияющие на диагностику различных патологических состояний. На данный момент оценка качества проводится вручную, что осложняется в условиях дистанционного описания исследований и высокой нагрузки. Нами был разработан Инструмент контроля качества, позволяющий автоматизировано оценивать наличие нарушений укладки и позиционирования пациента на рентгенограмме грудной клетки, а также выявлять ошибки заполнения метаинформации об исследовании в формате DICOM.</p> <p><bold>Цель исследования. </bold>Оценка эффективности работы Инструмента контроля качества в условиях реальной диагностической практики.</p> <p><bold>Методы. </bold>Пилотный эксперимент был проведен в 3 амбулаторно-поликлинических медицинских организациях города Москвы в течение двух месяцев. В рамках эксперимента было обработано Инструментом 9642 рентгенографических изображения грудной клетки. Затем изображения оценивались врачами-рентгенологами для подтверждения наличия нарушений качества.</p> <p><bold>Результаты. </bold>Среднее время обработки одного исследования составило 14 секунд. В ходе пилотного эксперимента было выявлено 3386 различных нарушений позиционирования пациента, встречающихся на от 14 до 45% рентгенографических изображений. Также было выявлено, что точность заполнения различной метаиформации об исследовании колеблется от 14 до 100%. Инструмент контроля качества справился с выявлением нарушений позиционирования пациента с AUC от 0,782 до 0,947 и с выявлением ошибок заполнения метаинформации с AUC от 0,985 до 1,0.</p> <p><bold>Заключение. </bold>Инструмент автоматизированного контроля качества показал себя перспективным в выявлении ошибок в заполнении метаинформации об исследовании и позиционирования пациента. Схема интеграции Инструмента в процесс контроля качества позволила получать результат оценки спустя 14 секунд после проведения исследований. В случае оптимизации пути исследования, это время может быть сокращено.</p></trans-abstract><trans-abstract xml:lang="zh"><p/></trans-abstract><kwd-group xml:lang="en"><kwd>Quality control</kwd><kwd>x-ray</kwd><kwd>artificial intelligence</kwd></kwd-group><kwd-group xml:lang="ru"><kwd>Контроль качества</kwd><kwd>рентгенография</kwd><kwd>искусственный интеллект</kwd></kwd-group><funding-group/></article-meta></front><body></body><back><ref-list><ref id="B1"><label>1.</label><mixed-citation>Hu J, Zhang C, Zhou K et al. Chest X-Ray Diagnostic Quality Assessment: How Much Is Pixel-Wise Supervision Needed? IEEE Trans Med Imaging. 2022 Jul;41(7):1711-1723. DOI: 10.1109/TMI.2022.3149171 EDN: HOWULD</mixed-citation></ref><ref id="B2"><label>2.</label><mixed-citation>Kjelle E, Chilanga C. The assessment of image quality and diagnostic value in X-ray images: a survey on radiographers' reasons for rejecting images. Insights Imaging. 2022 Mar 4;13(1):36. DOI: 10.1186/s13244-022-01169-9 EDN: OTXZTC</mixed-citation></ref><ref id="B3"><label>3.</label><mixed-citation>Лантух З. А., Кожихина Д. Д., Толкачев К. В. и др. Влияние качества рентгенологических исследований на коллективную эффективную дозу пациентов в условиях телемедицины. Digital Diagnostics. 2024; 5(3): 491-504. DOI: 10.17816/DD624990 EDN: ABZPHE</mixed-citation></ref><ref id="B4"><label>4.</label><mixed-citation>Морозов С.П., Кузьмина Е.С., Ледихова Н.В. и др. Мобилизация научно-практического потенциала службы лучевой диагностики г. Москвы в пандемию COVID-19. Digital Diagnostics. 2020; 1(1): 5-1. DOI: 10.17816/DD51043 EDN: YPAEPX</mixed-citation></ref><ref id="B5"><label>5.</label><mixed-citation>Морозов С.П., Ледихова Н.В., Панина Е.В. и др. Качество работы рентгенолаборантов в условиях дистанционного взаимодействия с референс-центром лучевой диагностики с применением телемедицинских технологий. Национальное здравоохранение. 2021;2(2):36-46. DOI: 10.47093/2713-069X.2021.2.2.36-46 EDN: LPGFGH</mixed-citation></ref><ref id="B6"><label>6.</label><mixed-citation>Gumieri DDF, Marques IS. Evaluation of Chest X-Ray Quality Parameters. Int J Radiol Imaging Technol (7):082. DOI: 10.23937/2572-3235.1510082.</mixed-citation></ref><ref id="B7"><label>7.</label><mixed-citation>Little KJ, Reiser I, Liu L et al. Unified Database for Rejected Image Analysis Across Multiple Vendors in Radiography. J Am Coll Radiol. 2017 Feb;14(2):208-216. DOI: 10.1016/j.jacr.2016.07.011</mixed-citation></ref><ref id="B8"><label>8.</label><mixed-citation>S. Ahmad, Muntaser &amp; Rumman, Mysara &amp; Malash et al.. Evaluation of positioning errors for in routine chest x-ray at beit jala governmental hospital. Australian Journal of Chemistry. 2018; 3(5):1-8.</mixed-citation></ref><ref id="B9"><label>9.</label><mixed-citation>Atkinson S, Neep M, Starkey D. Reject rate analysis in digital radiography: an Australian emergency imaging department case study. J Med Radiat Sci. 2020 Mar;67(1):72-79. DOI: 10.1002/jmrs.343</mixed-citation></ref><ref id="B10"><label>10.</label><mixed-citation>Борисов А.А., Арзамасов К.М., Семенов С.С. и др. Исследование возможностей алгоритмов автоматизированного контроля качества DICOM-метаданных рентгенографических исследований органов грудной клетки. Медицинская визуализация. 2024;28(2):134-144. DOI: 10.24835/1607-0763-1346 EDN: CBELBU</mixed-citation></ref><ref id="B11"><label>11.</label><mixed-citation>Vasilev, Y.; Vladzymyrskyy, A.; Omelyanskaya, O et al. AI-Based CXR First Reading: Current Limitations to Ensure Practical Value. Diagnostics (Basel). 2023 Apr 16;13(8):1430. DOI: 10.3390/diagnostics13081430 EDN: MPQYUP</mixed-citation></ref><ref id="B12"><label>12.</label><mixed-citation>Борисов А. А., Васильев Ю. А., Арзамасов К. М. Влияние нарушений качества рентгенографических исследований органов грудной клетки на работу врачей-рентгенологов и диагностического искусственного интеллекта. Менеджер здравоохранения. 2024; 7: 50-60. DOI: 10.21045/1811-0185-2024-7-50-60 EDN: JWMKBQ</mixed-citation></ref><ref id="B13"><label>13.</label><mixed-citation>Искусственный интеллект в лучевой диагностике: Per Aspera Ad Astra / Под ред. Ю.А. Васильева и А.В. Владзимирского. М.: Издательские решения, 2025. 491 с.</mixed-citation></ref><ref id="B14"><label>14.</label><mixed-citation>Свидетельство о государственной регистрации программы для ЭВМ № 2023617333 Российская Федерация. Модуль контроля качества результатов диагностических исследований по РГ ОГК : № 2023615822 : заявл. 28.03.2023 : опубл. 07.04.2023 / Ю. А. Васильев, А. В. Владзимирский, О. В. Омелянская [и др.]; заявитель Государственное бюджетное учреждение здравоохранения города Москвы «Научно-практический клинический центр диагностики и телемедицинских технологий Департамента здравоохранения города Москвы». EDN BSARZH.</mixed-citation></ref><ref id="B15"><label>15.</label><mixed-citation>Борисов А.А., Васильев Ю.А., Владзимирский А.В. и др. Применение технологий искусственного интеллекта как способ обеспечения качества выполнения рентгенографии органов грудной клетки. Менеджер здравоохранения. 2023; 7: 91-101. DOI: 10.21045/1811-0185-2023-7-91-101 EDN: SAFTMA</mixed-citation></ref><ref id="B16"><label>16.</label><mixed-citation>Бонтрагер, Кеннет Л.. Руководство по рентгенографии с рентгеноанатомическим атласом укладок: 2267 ил. / Кеннет Л. Бонтрагер; [пер. с англ. под ред. Линденбратена Л. Д., Китаева В. В., Уварова В. В.]. - 5-е изд. - Москва: ИНТЕЛМЕДТЕХНИКА, 2005. - 831 с.</mixed-citation></ref><ref id="B17"><label>17.</label><mixed-citation>Документация стандарта DICOM. Ссылка активна на 30.07.2025. https://www.dicomstandard.org/</mixed-citation></ref><ref id="B18"><label>18.</label><mixed-citation>Katri Nousiainen,Teemu Mäkelä,Anneli Piilonen,Juha I. Peltonen. Automating chest radiograph imaging quality control. Physica Medica. 2021; 83:138-145. DOI: 10.1016/j.ejmp.2021.03.014 EDN: ZXQTJO</mixed-citation></ref><ref id="B19"><label>19.</label><mixed-citation>Alvin Rajkomar, Sneha Lingam, Andrew G. Taylor et al. High-Throughput Classification of Radiographs Using Deep Convolutional Neural Networks. J Digit Imaging. 2017; 30(1): 95-101. DOI: 10.1007/s10278-016-9914-9 EDN: QLPHPQ</mixed-citation></ref></ref-list></back></article>
