Using artificial intelligence algorithms to approximate data from inertial measurement unit sensors and strain gauges in basketball players

Cover Page


Cite item

Full Text

Abstract

BACKGROUND: The process of acquiring visual data from microelectromechanical sensors currently requires significant time and effort on the part of the clinician. The use of artificial intelligence algorithms to approximate data could potentially reduce the time required and increase the amount of work performed.

AIM: The aim of this study is to approximate the data generated by sensors located in the shoe insole of basketball athletes and to compare the change in movement parameters of athletes when using CAD/CAM insoles.

MATERIALS AND METHODS: Prior to the commencement of the study, permission was obtained from the local ethical committee of Sechenov University (protocol No. 19–23). The main cohort consisted of 39 athletes, comprising 21 men (53%) and 18 women (47%). The mean age of the athletes was 22.4 ± 7.54 years. The athletes were divided into three equal comparison groups according to the type of insoles they were wearing. Throughout the study period, all athletes remained healthy and free from injuries. The assessment of movement in space was conducted using a three-test system. This involved the use of microelectromechanical system sensors with an artificial intelligence algorithm, which facilitated the construction of visually clear and well-interpreted median lines (data approximation).

RESULTS: For objective assessment of jumping characteristics, angular changes, velocity movements in space, and a comparison of all parameters on days 0 and 21, we developed and used our own software system, which was based on mathematical algorithmization and transformation formulas on specific axes. All data were entered into a neural network to construct averaged values of the parameters of movement in space. This approach allows the doctor to evaluate the changes of each peak movement on three different axes. Furthermore, it is possible to summarize the athlete's movement parameters with the aid of artificial intelligence, thereby enabling the detection of changes in different axes on days 0 and 21. Insole model C-1 exhibited the following improvements: X-axis movement speed (+7.7%), Y-axis jump height (+17.3%), endurance (+3.1%), and a 1.43-fold enhancement in shock absorption. Insole model C-2 exhibited an 8.4% increase in X-axis travel speed, a 20.8% enhancement in Y-axis jump height, a 6.6% improvement in endurance, and a 1.48-fold enhancement in shock absorption. Insole model C-3 demonstrated an 13.5% surge in X-axis travel speed, a 22.4% surge in Y-axis jump height, a 9.5% surge in endurance, and a 1.53-fold enhancement in shock absorption.

CONCLUSIONS: The approximation of the data (median lines using an artificial intelligence algorithm) allows for the straightforward interpretation and comparison of various parameters, as well as the drawing of conclusions regarding the efficacy of individual sports CAD/CAM insoles. Additionally, it enables the assessment of changes in endurance, speed of movement during prolonged and intensive movement, and the reduction of the risk of impact loads on the musculoskeletal system of the athlete.

Full Text

BACKGROUND: The process of acquiring visual data from microelectromechanical sensors currently requires significant time and effort on the part of the clinician. The use of artificial intelligence algorithms to approximate data could potentially reduce the time required and increase the amount of work performed.

AIM: The aim of this study is to approximate the data generated by sensors located in the shoe insole of basketball athletes and to compare the change in movement parameters of athletes when using CAD/CAM insoles.

MATERIALS AND METHODS: Prior to the commencement of the study, permission was obtained from the local ethical committee of Sechenov University (protocol No. 19–23). The main cohort consisted of 39 athletes, comprising 21 men (53%) and 18 women (47%). The mean age of the athletes was 22.4 ± 7.54 years. The athletes were divided into three equal comparison groups according to the type of insoles they were wearing. Throughout the study period, all athletes remained healthy and free from injuries. The assessment of movement in space was conducted using a three-test system. This involved the use of microelectromechanical system sensors with an artificial intelligence algorithm, which facilitated the construction of visually clear and well-interpreted median lines (data approximation).

RESULTS: For objective assessment of jumping characteristics, angular changes, velocity movements in space, and a comparison of all parameters on days 0 and 21, we developed and used our own software system, which was based on mathematical algorithmization and transformation formulas on specific axes. All data were entered into a neural network to construct averaged values of the parameters of movement in space. This approach allows the doctor to evaluate the changes of each peak movement on three different axes. Furthermore, it is possible to summarize the athlete's movement parameters with the aid of artificial intelligence, thereby enabling the detection of changes in different axes on days 0 and 21. Insole model C-1 exhibited the following improvements: X-axis movement speed (+7.7%), Y-axis jump height (+17.3%), endurance (+3.1%), and a 1.43-fold enhancement in shock absorption. Insole model C-2 exhibited an 8.4% increase in X-axis travel speed, a 20.8% enhancement in Y-axis jump height, a 6.6% improvement in endurance, and a 1.48-fold enhancement in shock absorption. Insole model C-3 demonstrated an 13.5% surge in X-axis travel speed, a 22.4% surge in Y-axis jump height, a 9.5% surge in endurance, and a 1.53-fold enhancement in shock absorption.

CONCLUSIONS: The approximation of the data (median lines using an artificial intelligence algorithm) allows for the straightforward interpretation and comparison of various parameters, as well as the drawing of conclusions regarding the efficacy of individual sports CAD/CAM insoles. Additionally, it enables the assessment of changes in endurance, speed of movement during prolonged and intensive movement, and the reduction of the risk of impact loads on the musculoskeletal system of the athlete.

×

About the authors

Ekaterina M. Barskova

The First Sechenov Moscow State Medical University

Email: doc.barskova@gmail.com
ORCID iD: 0000-0003-4683-795X
SPIN-code: 3988-7003
Russian Federation, Moscow

Aleksandr D. Kuklev

The First Sechenov Moscow State Medical University

Author for correspondence.
Email: kuklev_a@list.ru
ORCID iD: 0009-0004-8778-7244
Russian Federation, Moscow

Nikolay V. Polukarov

The First Sechenov Moscow State Medical University

Email: nvpolukarov@mail.ru
ORCID iD: 0000-0002-5035-7265
SPIN-code: 1886-7044
Russian Federation, Moscow

Evgeny E. Achkasov

The First Sechenov Moscow State Medical University

Email: 2215.g23@rambler.ru
ORCID iD: 0000-0001-9964-5199
SPIN-code: 5291-0906
Russian Federation, Moscow

References

  1. Warden SJ, Edwards WB, Willy RW. Preventing Bone Stress Injuries in Runners with Optimal Workload. Curr Osteoporos Rep. 2021;19(3):298–307. doi: 10.1007/s11914-021-00666-y
  2. Hostrup M, Bangsbo J. Performance Adaptations to Intensified Training in Top-Level Football. Sports Med. 2023;53(3):577–594. doi: 10.1007/s40279-022-01791-z
  3. Zhukova EV, Achkasov EE, Polukarov NV. Influence of the individual approach of conservative therapy of flatfoot on reducing the pain syndrome and improving the quality of life of patients. Bulletin of Rehabilitation Medicine. 2019;5(93):74–80. EDN: ZKGTWQ
  4. Jonnala UK, Sankineni R, Ravi Kumar Y. Design and development of fused deposition modeling (FDM) 3D-Printed Orthotic Insole by using gyroid structure. J Mech Behav Biomed Mater. 2023;145. doi: 10.1016/j.jmbbm.2023.106005
  5. Nickerson KA, Li EY, Telfer S, Ledoux WR, Muir BC. Exploring the mechanical properties of 3D-printed multilayer lattice structures for use in accommodative insoles. J Mech Behav Biomed Mater. 2024;150. doi: 10.1016/j.jmbbm.2023.106309
  6. Daryabor A, Kobayashi T, Saeedi H, et al. Effect of 3D printed insoles for people with flatfeet: A systematic review. Assist Technol. 2023;35(2):169–179. doi: 10.1080/10400435.2022.2105438
  7. Danko M, Sekac J, Dzivakova E, Zivcak J, Hudak R. 3D Printing of Individual Running Insoles — A Case Study. Orthop Res Rev. 2023;15:105–118. doi: 10.2147/ORR.S399624
  8. Hasan H, Davids K, Chow JY, Kerr G. Compression and texture in socks enhance football kicking performance. Hum Mov Sci. 2016;48:102–111. doi: 10.1016/j.humov.2016.04.008
  9. Jandova S, Mendricky R. Benefits of 3D Printed and Customized Anatomical Footwear Insoles for Plantar Pressure Distribution. 3D Print Addit Manuf. 2022;9(6):547–556. doi: 10.1089/3dp.2021.0002
  10. Hsu CY, Wang CS, Lin KW, et al. Biomechanical Analysis of the FlatFoot with Different 3D-Printed Insoles on the Lower Extremities. Bioengineering (Basel). 2022;9(10):563. doi: 10.3390/bioengineering9100563
  11. Jin H, Xu R, Wang J. The Effects of Short-Term Wearing of Customized 3D Printed Single-Sided Lateral Wedge Insoles on Lower Limbs in Healthy Males: A Randomized Controlled Trial. Med Sci Monit. 2019;25:7720–7727. doi: 10.12659/MSM.919400
  12. Grouvel G, Carcreff L, Moissenet F, Armand S. A dataset of asymptomatic human gait and movements obtained from markers, IMUs, insoles and force plates. Sci Data. 2023;10(1):180. doi: 10.1038/s41597-023-02077-3
  13. Menez C, L'Hermette M, Coquart J. Orthotic Insoles Improve Gait Symmetry and Reduce Immediate Pain in Subjects With Mild Leg Length Discrepancy. Front Sports Act Living. 2020;2:579152. doi: 10.3389/fspor.2020.579152
  14. Shi QQ, Li PL, Yick KL, Jiao J, Liu Q.L. Influence of Contoured Insoles with Different Materials on Kinematics and Kinetics Changes in Diabetic Elderly during Gait. Int J Environ Res Public Health. 2022;19(19):12502. doi: 10.3390/ijerph191912502
  15. Wang B, Sun Y, Guo X, et al. The efficacy of 3D personalized insoles in moderate adolescent idiopathic scoliosis: a randomized controlled trial. BMC Musculoskelet Disord. 2022;23(1):983. doi: 10.1186/s12891-022-05952-z
  16. Peebles AT, Ford KR, Taylor JB, et al. Using force sensing insoles to predict kinetic knee symmetry during a stop jump. J Biomech. 2019;95:109293. doi: 10.1016/j.jbiomech.2019.07.037
  17. Costa BL, Magalhães FA, Araújo VL, et al. Is there a dose-response of medial wedge insoles on lower limb biomechanics in people with pronated feet during walking and running. Gait Posture. 2021;90:190–196. doi: 10.1016/j.gaitpost.2021.09.163
  18. Zhukova EV, Achkasov EE, Polukarov NV, et al. Influence of the biomechanics of walking on the formation of foot pathologies. Clinical Practice in Pediatrics. 2018;13(4):91–97. EDN: VQBSBY doi: 10.20953/1817-7646-2018-4-91-97

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2024 Eco-Vector

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

СМИ зарегистрировано Федеральной службой по надзору в сфере связи, информационных технологий и массовых коммуникаций (Роскомнадзор).
Регистрационный номер и дата принятия решения о регистрации СМИ: серия ПИ № ФС 77 - 79539 от 09 ноября 2020 г.