Position-force control in the identification of tissue structures using the spectrophotometric method
- Authors: Belsheva M.N.1, Guseva A.V.1, Koleda F.A.1, Murlina P.V.1, Safonova L.P.1
-
Affiliations:
- Bauman Moscow State Technical University
- Issue: Vol 5, No 1S (2024)
- Pages: 12-14
- Section: Articles by YOUNG SCIENTISTS
- Submitted: 08.02.2024
- Accepted: 01.03.2024
- Published: 03.07.2024
- URL: https://jdigitaldiagnostics.com/DD/article/view/626641
- DOI: https://doi.org/10.17816/DD626641
- ID: 626641
Cite item
Full Text
Abstract
BACKGROUND: Time-resolved spectrophotometry enables the contact probing of biological tissues at a depth of two millimeters to several centimeters, with a spatial resolution of one to five millimeters. This technique provides a quantitative assessment of optical parameters, concentrations of main chromophores, identification of tissue type and inclusions in the volume, which is relevant for intraoperative diagnostics [1–3]. The variability of optical properties during probe squeezing necessitates the implementation of force control of squeezing, which, like positioning, is used in robotic surgery and diagnostics [4–11]. A combined mechanical and spectrophotometric approach holds promise in this regard. However, further research is required concerning spectrophotometer setup, the development of test objects, and the determination of the possibilities of positioning-force-controlled spectrophotometry for the identification of tissues and inclusions.
Development of approaches to active positional force control to study the functionality of spectrophotometry in identifying tissue structures.
MATERIALS AND METHODS: An experimental bench was constructed based on a two-wavelength spectrophotometer with OxiplexTS frequency approach (ISS Inc., USA). This bench allows for the position control of the optical probe using a robotic mini-manipulator (U-Arm, China). Additionally, a software program was developed to record the pressing force of the fabricated probe in a customized nozzle for the manipulator. Finally, an algorithm was proposed for processing experimental data to estimate biomechanical, optical, and physiological parameters of the tissue. A single healthy subject participated in the experimental study. Measurements were conducted on the dorsal and ventral surfaces of the forearm and on the palmar surface of the hypotenar.
RESULTS: The quantitative assessment of elastic properties of biological tissue can be achieved through the use of force-displacement data. The simultaneous registration of optical parameters, concentrations of hemoglobin fractions in a unit of the investigated volume, and tissue saturation in the dynamics of probe pressing allows for the estimation of microcirculatory blood flow, the revelation of the presence and type of large vessels. The standard silicone test objects used for spectrophotometer calibration do not align with the mechanical properties of biological tissues. Given the diminutive dimensions of the optical probe, this discrepancy introduces an additional degree of uncertainty in the quantitative assessment of tissue properties.
CONCLUSIONS: The addition of active force control and automated positioning of the optical probe during spectrophotometry enhances its functional capabilities for identifying tissue structures and expands its applications in robotic pre-, intra- and post-operative diagnostics. For further studies on a larger number of tissues, tissue structures and mimicking tissue test objects, an improvement of the experimental bench is required: increase of the sensitivity of the force sensor, smoothness and discreteness of the motion during positioning, e.g. by replacing the mini manipulator by a collaborative robot. The improvement of the software part implies the implementation of synchronization with OxiplexTS through its input interface module, writing a program for automatic surface scanning.
Full Text
BACKGROUND: Time-resolved spectrophotometry enables the contact probing of biological tissues at a depth of two millimeters to several centimeters, with a spatial resolution of one to five millimeters. This technique provides a quantitative assessment of optical parameters, concentrations of main chromophores, identification of tissue type and inclusions in the volume, which is relevant for intraoperative diagnostics [1–3]. The variability of optical properties during probe squeezing necessitates the implementation of force control of squeezing, which, like positioning, is used in robotic surgery and diagnostics [4–11]. A combined mechanical and spectrophotometric approach holds promise in this regard. However, further research is required concerning spectrophotometer setup, the development of test objects, and the determination of the possibilities of positioning-force-controlled spectrophotometry for the identification of tissues and inclusions.
Development of approaches to active positional force control to study the functionality of spectrophotometry in identifying tissue structures.
MATERIALS AND METHODS: An experimental bench was constructed based on a two-wavelength spectrophotometer with OxiplexTS frequency approach (ISS Inc., USA). This bench allows for the position control of the optical probe using a robotic mini-manipulator (U-Arm, China). Additionally, a software program was developed to record the pressing force of the fabricated probe in a customized nozzle for the manipulator. Finally, an algorithm was proposed for processing experimental data to estimate biomechanical, optical, and physiological parameters of the tissue. A single healthy subject participated in the experimental study. Measurements were conducted on the dorsal and ventral surfaces of the forearm and on the palmar surface of the hypotenar.
RESULTS: The quantitative assessment of elastic properties of biological tissue can be achieved through the use of force-displacement data. The simultaneous registration of optical parameters, concentrations of hemoglobin fractions in a unit of the investigated volume, and tissue saturation in the dynamics of probe pressing allows for the estimation of microcirculatory blood flow, the revelation of the presence and type of large vessels. The standard silicone test objects used for spectrophotometer calibration do not align with the mechanical properties of biological tissues. Given the diminutive dimensions of the optical probe, this discrepancy introduces an additional degree of uncertainty in the quantitative assessment of tissue properties.
CONCLUSIONS: The addition of active force control and automated positioning of the optical probe during spectrophotometry enhances its functional capabilities for identifying tissue structures and expands its applications in robotic pre-, intra- and post-operative diagnostics. For further studies on a larger number of tissues, tissue structures and mimicking tissue test objects, an improvement of the experimental bench is required: increase of the sensitivity of the force sensor, smoothness and discreteness of the motion during positioning, e.g. by replacing the mini manipulator by a collaborative robot. The improvement of the software part implies the implementation of synchronization with OxiplexTS through its input interface module, writing a program for automatic surface scanning.
About the authors
Mariia N. Belsheva
Bauman Moscow State Technical University
Author for correspondence.
Email: belsheva.masha@gmail.com
ORCID iD: 0000-0003-3809-6397
Russian Federation, Moscow
Anastasia V. Guseva
Bauman Moscow State Technical University
Email: anastas_g01@mail.ru
ORCID iD: 0009-0006-1787-4726
Russian Federation, Moscow
Fedor A. Koleda
Bauman Moscow State Technical University
Email: fkoleda@bk.ru
ORCID iD: 0009-0000-1742-2355
Russian Federation, Moscow
Polina V. Murlina
Bauman Moscow State Technical University
Email: pmurlina@mail.ru
ORCID iD: 0009-0004-3111-2379
Russian Federation, Moscow
Larisa P. Safonova
Bauman Moscow State Technical University
Email: larisa.safonova@gmail.com
ORCID iD: 0000-0001-6607-7359
SPIN-code: 3522-7990
Russian Federation, Moscow
References
- Fantini S, Sassaroli A. Frequency-domain techniques for cerebral and functional near-infrared spectroscopy. Frontiers in neuroscience. 2020;14:300. doi: 10.3389/fnins. 2020.00300
- Barstow TJ. Understanding near infrared spectroscopy and its application to skeletal muscle research. Journal of Applied Physiology. 2019;126(5):1360–1376. doi: 10.1152/japplphysiol.00166. 2018
- Safonova LP, Orlova VG, Shkarubo AN. Investigation of Neurovascular Structures Using Phase-Modulation Spectrophotometry. Optics and Spectroscopy. 2019;126:745–757. doi: 10.1134/S0030400X19060201
- Zhang XU, Faber DJ, van Leeuwen TG, Sterenborg HJCM. Effect of probe pressure on skin tissue optical properties measurement using multi-diameter single fiber reflectance spectroscopy. Journal of Physics: Photonics. 2020;2(3):034008. doi: 10.1088/2515-7647/ab9071
- Abookasis D, Malchi D, Robinson D, Yassin M. Pressure estimation via measurement of reduced light scattering coefficient by oblique laser incident reflectometry. Journal of Laser Applications. 2024;36(1). doi: 10.2351/7.0001263
- Bregar M, Bürmen M, Aljancic U, et al. Contact pressure-aided spectroscopy. Journal of biomedical optics. 2014;19(2):020501. doi: 10.1117/1.JBO.19.2.020501
- Cugmas B, Bregar M, Bürmen M, Pernuš F, Likar B. Impact of contact pressure–induced spectral changes on soft-tissue classification in diffuse reflectance spectroscopy: problems and solutions. Journal of biomedical optics. 2014;19(3):037002. doi: 10.1117/1.JBO.19.3.037002
- Cugmas B, Bürmen M, Bregar M, Pernuš F, Likar B. Pressure-induced near infrared spectra response as a valuable source of information for soft tissue classification. Journal of biomedical optics. 2013;18(4):047002. doi: 10.1117/1.JBO.18.4.047002
- Cheng X, Xu X. Study of the pressure effect in near-infrared spectroscopy. Optical Tomography and Spectroscopy of Tissue V. SPIE. 2003;4955:397–406. doi: 10.1117/12.476783
- Ahmed I, Ali M, Butt H. Investigating the Influence of Probe Pressure on Human Skin Using Diffusive Reflection Spectroscopy. Micromachines. 2023;14(10):1955. doi: 10.3390/mi14101955
- Patent RUS № 2758868/ 02.11.2021. Byul. № 31. Safonova LP, Shkarubo AN, Belikov NV, Fedorenko VI, Kolpakov AV. System for intraoperative detection and recognition of neurovascular structures in the volume of biological tissue. EDN: KQMGQM
Supplementary files