Low-dose computed tomography for the diagnosis of COVID-19

Cover Page


Cite item

Full Text

About the authors

D. A. Rumyantsev

The First Sechenov Moscow State Medical University under Ministry of Health of the Russian Federation

Email: x.radiology@mail.ru
Russian Federation, Moscow

I. A. Blokhin

Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of Moscow Health Care Department

Email: x.radiology@mail.ru
Russian Federation, Moscow

A. P. Gonchar

Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of Moscow Health Care Department

Email: x.radiology@mail.ru
Russian Federation, Moscow

V. A. Gombolevsky

Artificial Intelligence Research Institute

Email: x.radiology@mail.ru
Russian Federation, Moscow

R. V. Reshetnkov

The First Sechenov Moscow State Medical University under Ministry of Health of the Russian Federation; Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of Moscow Health Care Department

Author for correspondence.
Email: x.radiology@mail.ru
Russian Federation, Moscow; Moscow

References

  1. Akl EA, Blažić I, Yaacoub S, et al. Use of Chest Imaging in the Diagnosis and Management of COVID-19: A WHO Rapid Advice Guide. Radiology. 2021;298(2):E63–E69. doi: 10.1148/radiol.2020203173
  2. Jalaber C, Lapotre T, Morcet-Delattre T, et a. Chest CT in COVID-19 pneumonia: A review of current knowledge. Diagn Interv Imaging. 2020;101(7–8):431–437. doi: 10.1016/j.diii.2020.06.001
  3. Dangis A, Gieraerts C, Bruecker YD, et al. Accuracy and reproducibility of low-dose submillisievert chest CT for the diagnosis of COVID-19. Radiol Cardiothorac Imaging. 2020;2(2):e200196. doi: 10.1148/ryct.2020200196
  4. Radpour A, Bahrami-Motlagh H, Taaghi MT, et al. COVID-19 evaluation by low-dose high resolution CT scans protocol. Acad Radiol. 2020;27:901. doi: 10.1016/j.acra.2020.04.016
  5. Christner JA, Braun NN, Jacobsen MC, et al. Size-specific dose estimates for adult patients at CT of the torso. Radiology. 2012;265(3):841–847. doi: 10.1148/radiol.12112365
  6. Huda W, Mettler FA. Volume CT dose index and dose-length product displayed during CT: what good are they? Radiology. 2011;258:236–242. doi: 10.1148/radiol.10100297
  7. Brady SL, Mirro AE, Moore BM, Kaufman RA. How to appropriately calculate effective dose for CT using either size-specific dose estimates or dose-length product. Am J Roentgenol. 2015;204:953–958. doi: 10.2214/AJR.14.13317

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2022 Rumyantsev D.A., Blokhin I.A., Gonchar A.P., Gombolevsky V.A., Reshetnkov R.V.

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

СМИ зарегистрировано Федеральной службой по надзору в сфере связи, информационных технологий и массовых коммуникаций (Роскомнадзор).
Регистрационный номер и дата принятия решения о регистрации СМИ: серия ПИ № ФС 77 - 79539 от 09 ноября 2020 г.


This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies